Search Result - Kits

  • Xanthine Assay Kit
  • Cat. No: ARG82197
  • Reactivity: Hu, Ms, Rat, All
  • Application: FuncSt
  • Sample type: Serum and cell lysate.
  • Sensitivity: 10 µM (colorimetric); 3 µM (fluorometric)
  • Detection Range: 10 - 2000 µM (colorimetric) and 3 - 200 µM (fluorometric)
  • Human S100A6 ELISA Kit
  • publication_list (2 Publications)
  • Cat. No: ARG82251
  • Reactivity: Hu
  • Application: ELISA
  • Specificity: Not react with following recombinant human proteins: ApoAI, BMP1, BMP2, BMP3, BMP4, BMP7, CRP, HGF, HSP27, IL1 alpha, IL1 RI, IL1 beta, IL1RA, IL2, IL4, IL5, IL6, IL8, IL10, IL12, IL13, IL15, IL17C, IL21, IL23, IFN gamma, MMP2, sIL2R, sIL6R, PDGF, PLA2G7, prolactin, S100A1, S100B, S100A9, S100A12, TGF beta 1, TGF beta 2, TGF beta 3, TLR1, TLR2, TLR3, TNF alpha, TNF RI, TNF RII and VEGF.
  • Sample type: Serum, plasma and cell culture supernatants.
  • Sensitivity: 31 pg/ml
  • Standard Range: 62 - 4000 pg/ml
  • Conjugation: HRP
  • Human MMP8 Assay Kit
  • publication_list (1 Publications)
  • Cat. No: ARG82630
  • Reactivity: Hu
  • Application: FuncSt
  • Specificity: Measures endogenous active MMP8 (naturally occurring) or total active MMP8 (following activation with APMA).
  • Sample type: Serum, plasma, cell culture supernatants, urine, saliva and tissue homogenates.
  • Sensitivity: 100 pg/ml for 2 hours incubation
    24 pg/ml for 6 hours incubation
    4 pg/ml for 24 hours incubation
  • Detection Range: 10 - 24000 pg/ml
  • Arg8 Vasopressin ELISA Kit
  • Cat. No: ARG83003
  • Reactivity: Hu, Ms, Rat, Dog, Sheep
  • Application: ELISA
  • Specificity: Cross-Reactivity:
    [Arg8]-Vasopressin (Human, Mouse, Rat, Ovine, Canine): 100%; [Arg8]-Vasotocin: 54%; [Lys8]-Vasopressin (Human, Rat, Mouse, Ovine), Deamino-[D-Arg8]-Vassopressin, Oxytocin, LH-RH, ACTH (Human), alpha-ANP (1-28) (Human, Canine), Met-Enkephalin, PACAP38 (Human, Ovine, Rat) and PACAP27-NH2 (Human, Ovine, Rat): 0%.
  • Sample type: Plasma (Sample extraction is recommended)
  • Sensitivity: 0.04 ng/ml
  • Standard Range: 0.01 - 100 ng/ml
  • Detection Range: 0.04 - 0.51 ng/ml
  • Conjugation: HRP
  • LH-RH / Gn-RH ELISA Kit
  • Cat. No: ARG80913
  • Reactivity: Hu, Ms, Rat, Pig
  • Application: ELISA
  • Specificity: Cross-reactivity: LH-RH (Human, Porcine, Rat) (100%);
    LH-RH (Lamprey) (0%);
    LH-RH (Salmon) (0%);
    [D-Trp6, Des-Gly10]-LH-RH Ethylamide (0%);
    [D-Ala6, Des-Gly10]-LH-RH Ethylamide (0%);
    GAP (Human) (0%);
    GRF (Human) (0%);
    ACTH (Human) (0%)
  • Sample type: Blood collection, Plasma extraction, Tissue extraction and CSF extraction
  • Sensitivity: 0.05 ng/ml
  • Standard Range: 0 - 25 ng/ml
  • Detection Range: 0.05 - 1.16 ng/ml
  • Conjugation: HRP
  • Irisin ELISA Kit
  • Cat. No: ARG81195
  • Reactivity: Hu, Ms, Rat, Dog
  • Application: ELISA
  • Specificity: Irisin, Recombinant (Human, Rat, Mouse, Dog): 100%
    Irisin (aa. 1-112) (Human, Mouse, Rat, Dog): 100%
    FNDC5, isoform 4 recombinant (Human, Mouse, Rat, Dog): 9%
    Irisin precursor, C-terminal 48mer: Human FNDC5 (aa. 165-212); Mouse, Rat FNDC5 (aa. 162-209): 0%
    Irisin (aa. 42-95) (Human, Mouse, Rat, Dog): 0%
  • Sample type: plasma (EDTA) and serum
  • Sensitivity: 2.62 ng/ml
  • Standard Range: 0.1 - 1000 ng/ml
  • Detection Range: 0.1 - 1000 ng/ml
  • Conjugation: HRP
  • Glucagon ELISA Kit
  • Cat. No: ARG81293
  • Reactivity: Hu, Ms, Rat, Pig
  • Application: ELISA
  • Specificity: No significant cross-reactivity or interference with the factors below was observed:Glucentin-Related Polypeptide (aa 21-50), Glucagon-Like Peptide 1 (aa 92-128) and Glucagon-Like Peptide 2 (aa 146-178).
  • Sample type: Serum, plasma or cell culture supernatants.
  • Sensitivity: 30 pg/ml
  • Standard Range: 62.5 - 4000 pg/ml
  • Conjugation: HRP
  • Mouse / Rat Insulin (Ultra sensitive) ELISA Kit
  • publication_list (1 Publications)
  • Cat. No: ARG81295
  • Reactivity: Ms, Rat
  • Application: ELISA
  • Specificity: Mouse / Rat Insulin: 100%
    Hamster Insulin: Detected
    Rat C-peptide, Rat pancreatic polypeptide, Porcine glucagon, Human Insulin like growth factor-I and II: Not Detected
  • Sample type: Serum, plasma and cell culture supernatants.
  • Sensitivity: 50 pg/ml (5 µl sample volume); 5 pg/ml (100 µl sample volume)
  • Standard Range: 0.1 - 6.4 ng/ml
  • Conjugation: HRP